KAWAMOTO Package Booster Pump System


KF-R

KF-R

Product code: KF-R

Application

  • Automatic water supply from ground and underground reservoir
  • Water supply to buildings and factories
  • Condominium, hotel, hospital, commercial building, etc.
  • Small regional drinking water
  • Other general water supply

Feature

  • A number of operation unit control type of KF2, performing from 2 units to 6 units rotary operation.
  • Easy maintenance due to the individual ball valve for each pump.
  • Reliable back up function. water supply suspension are avoided as much as possible with the backup functions that activate when there is pump failure, inverter failure as well as pressure transmitter failure and control PC Board failure.
  • Water level control system is compatible to twin reservoir and 5 electrodes, standardly integrating inflow valve control circuit and terminal for attaching heater.
  • Stainless steel precision casting The pump casing and flanges are made from precision cast stainless steel to withstand heavy load and free from strain. The connection section is mainly made of stainless steel, and resin, and the bronze components prevent
  • Adoption of low noise type TEFC motor. All models are equipped with a low-noise TEFC motor as a standard. Highly Resistant to insulation deterioration due to dust and moisture and has a long machine life.
  • High responsiveness and High pumping performance. Adopted a new control method with quick pressure response and low pressure fluctuation. With the high pimping performance of the high efficiency three-dimensional impeller, water supply is quiet, powerful
  • Compact and light weight for installation work improvement. Accomplished 45% reducing an inner volume in max. compared with previous model. Discharge direction is selectable in either right or left.
  • Heater terminal is attached. Standardly equipped with heater terminal. Easy attaching of heater.
  • Temperature detective function It has the function to stop the pump when the pump internal water temperature rises.
  • Unified dual frequency specification. It is available either in 50Hz and 60Hz. And also, either in positive and negative suction.
 

 

Standard spec

Control method

Control method: Constant estimated terminal pressure by frequency control

Operation method

Operation method: 2~6 units rotary

Installation location

Installation location: Indoor (Ambient temperature: 0 to 40°C, Humidity: 90% or less, Altitude: 1,000m or less)

Application liquid

Application liquid: Clean water 0~40°C (no freezing)

Pump (material)

Pump (material): KR-C type stainless multistage pump (Impeller: resin or stainless cast steel (304) or bronze, Shaft: SUS304 (portion contacting liquid), Casing: stainless cast steel (304))

Motor

Motor: TEFC indoor
Motor: Poles: 2 (max. frequency in automatic operation: 60Hz)
Motor: Efficiency: Premium efficiency (IE3) *High efficiency in 5.5kW

Suction condition

Suction condition: Inflow (0~5m *0~3 in 5.5kW model with 40mm suction bore size, and 7.5kW models with 50mm suction bore size *inquire if back pressure exceeds 5m) or suction lift up (within -6m total suction head *actual suction head should be less than -4m, within

Flange figure

Flange figure: JIS 10K thin type (discharge side is not included)

Paint color (Munsell No.)

Paint color (Munsell No.): Control panel: beige (5Y7/1), Accumulator: gray (10Y5.5/0.5) , Others: gray (2.5PB5.1/0.8)

 

Standard Accessories

Control panel: ECSG3-R type

Flow sensor

Pressure transmitter

Check valve: (stainless hummer less check valve)

Accumulator: (PTD3-2AS type)

Pressure gage

Others: Companion flange, base and ball valve

 

Optional Accessories

Heater
Vibration proof bed
Electrode, electrode holder
Foot valve (in case suction lift up use)
Foundation bolt
Pump cover
Level relay (for low water level detection, 0.75kW or less)
AC reactor panel

 

 

 

 

Related Products


KFEH KFEH
Hot Water Super Energy Saving Package Booster Pump Major Application: Potable water supply, General water supply, Boiler water supply, Industrial Max. bore (Suc. x Dis.): 50 x 65mm Max. Q: 0.78m3/min (206 GPM) Max. H: 71m (232 feet)
KFE-T KFE-T
Super Energy Saving Package Booster Pump Major Application: Potable water supply, General water supply, Sewage treatment, Industrial Max. bore (Suc. x Dis.): 65 x 100 mm Max. Q: 1.85m3/min (488 GPM) Max. H: 110m (359 feet)
KFE-A/P KFE-A/P
Inverter package booster Major Application: Potable water supply, General water supply, Household, Agriculture & Irrigation Max. bore (Suc. x Dis.):  65 x 80 mm Max. Q:  1.2m3/min (317 GPM) Max. H:  80m (261 feet)      
KF-T KF-T
Inverter package booster up to 3 units Major Application : Potable water supply, General water supply Max. bore (Suc. x Dis.): 65 x 100 mm Max. Q: 1.78m3/min (470 GPM) Max. H: 80m (261 feet)
KF-H KF-H
Inverter Package Booster Pumps For Skyscraper Major Application: Potable water supply, General water supply Max. bore (Suc. x Dis.): 50 x 125 mm Max. Q: 2.55m3/min (673 GPM) Max. H: 170m (555 feet)
KB KB
Package Booster Pump Major Application: Potable water supply, general water supply, Household, Agriculture & Irrigation Max. bore (Suc. x Dis.): 65 x 80 mm Max. Q: 1.2m3/min (317 GPM) Max. H: 80m (261 feet)
02822132969